CUT BACK – MC GRADE

Home » Bitumen » CUT BACK – MC GRADE

Whats is bitumen?

What is CUTBACK Bitumen?

Cutback bitumen is a petroleum product produced by diluting bitumen in petroleum hydrocarbon (Kerosene). The aim is to decrease the viscosity and to increase the penetration of bitumen on asphalt surface. In comparison with bitumen, cutback bitumen is sprayed on different layers of roads in a notably lower temperature. Once the solvent is evaporated, the remaining bitumen equals with penetration bitumen in terms of hardness.

Rapid Curing Grades:

  • RC 70: contains 55% bitumen, black in color
    • Application: Surface treatment, Prime coat on open surfaces, Prime coat on tight surfaces, Tack coat, Dust binder, Mulch treatment.
    • Packing: Reconditioned steel drums 220 lit (191 ± 3 Kg), New steel drums 220lit., (191 ± 3 Kg), Bulk (IBC Tank), flexi tank
  • RC 250: contains 65% bitumen, black in color
    • Application: Surface treatment, Prime coat on open surfaces.
    • Packing: Reconditioned steel drums 220 lit (191 ± 3 Kg), New steel drums 220lit., (191 ± 3 Kg), Bulk (IBC Tank), flexi tank
  • RC 800: contains 75% bitumen, black in color
    • Application: Surface treatment, single surface treatment, multiple surface treatment.
    • Packing: Reconditioned steel drums 220 lit (191 ± 3 Kg), New steel drums 220lit., (191 ± 3 Kg), Bulk (IBC Tank), flexi tank.
  • RC 3000: contains 80% bitumen, black in color
    • Application: Surface treatment, single surface treatment, multiple surface treatment.
    • Packing: Reconditioned steel drums 220 lit (191 ± 3 Kg), New steel drums 220lit., (191 ± 3 Kg), Bulk (IBC Tank), flexi tank

Medium Curing Grades:

  • MC 30: contains 58% bitumen and has the lowest viscosity among all grades, black in color
    • Application: Prime Coat on Tight Surface, Tack Coat, Road Mix.
    • Packing: Reconditioned steel drums 220 lit (191 ± 3 Kg), New steel drums 220lit., (191 ± 3 Kg), Bulk (IBC Tank), flexi tank
  • MC 70: contains 64% bitumen, black in color
    • Application: Prime coat on open surfaces, Prime Coat on Tight Surface, Dust binder.
    • Packing: Reconditioned steel drums 220 lit (191 ± 3 Kg), New steel drums 220lit., (191 ± 3 Kg), Bulk (IBC Tank), flexi tank
  • MC 250: contains 74% bitumen, black in color
    • Application: Prime coat on open surfaces, sand seal.
    • Packing: Reconditioned steel drums 220 lit (191 ± 3 Kg), New steel drums 220lit., (191 ± 3 Kg), Bulk (IBC Tank), flexi tank
  • MC 800: contains 80% bitumen, black in color
    • Application: single surface treatment, sand seal.
    • Packing: Reconditioned steel drums 220 lit (191 ± 3 Kg), New steel drums 220lit., (191 ± 3 Kg), Bulk (IBC Tank), flexi tank
  • MC 3000: contains 85% bitumen, black in color
    • Application: single surface treatment, multiple surface treatment.
    • Packing: Reconditioned steel drums 220 lit (191 ± 3 Kg), New steel drums 220lit., (191 ± 3 Kg), Bulk (IBC Tank), flexi tank

 

Bitumen RC-70
PropertySpecification LimitTest Method
MinMax
Kinematic viscosity at 60°c ,cST70140ASTM D2170
Flash point(tag open cup), °c--ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°f(360°c)
to 437°f(225°c)50-ASTM D402
To 500°f(260°c)70-
to 600°f(316°c)85-
Residue from distillation to680°f(360°c), percent volume by difference55-
Test on Residue from distillation test
Penetration 77°f(25°c) 100g,5s mm80120ASTM D5
Ductility 77°f(25°c) 5cm/min cm100-ASTM D113
Solubility in trichloroethylene %99-ASTM D2042
Water, percent volume-0.2ASTM D95
Bitumen RC-250
PropertySpecification LimitTest Method
MinMax
Kinematic viscosity at 60°c ,cST250500ASTM D2170
Flash point(tag open cup), °c-27ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°f(360°c)
to 437°f(225°c)35-ASTM D402
To 500°f(260°c)60-
to 600°f(316°c)80-
Residue from distillation to680°f(360°c), percent volume by difference65-
Test on Residue from distillation test
Penetration 77°f(25°c) 100g,5s mm80120ASTM D5
Ductility 77°f(25°c) 5cm/min cm100-ASTM D113
Solubility in trichloroethylene %99-ASTM D2042
Water, percent volume-0.2ASTM D95
Bitumen RC-800
PropertySpecification LimitTest Method
MinMax
Kinematic viscosity at 60°c ,cST8001600ASTM D2170
Flash point(tag open cup), °c27-ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°f(360°c)
to 437°f(225°c)15-ASTM D402
To 500°f(260°c)45-
to 600°f(316°c)75-
Residue from distillation to680°f(360°c), percent volume by difference75-
Test on Residue from distillation test
Penetration 77°f(25°c) 100g,5s mm80120ASTM D5
Ductility 77°f(25°c) 5cm/min cm100-ASTM D113
Solubility in trichloroethylene %99-ASTM D2042
Water, percent volume-0.2ASTM D95
Bitumen RC-3000
PropertySpecification LimitTest Method
MinMax
Kinematic viscosity at 60°c ,cST30006000ASTM D2170
Flash point(tag open cup), °c-27ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°f(360°c)
to 437°f(225°c)--ASTM D402
To 500°f(260°c)25-
to 600°f(316°c)70-
Residue from distillation to680°f(360°c), percent volume by difference80-
Test on Residue from distillation test
Penetration 77°f(25°c) 100g,5s mm80120ASTM D5
Ductility 77°f(25°c) 5cm/min cm100-ASTM D113
Solubility in trichloroethylene %99-ASTM D2042
Water, percent volume-0.2ASTM D95
Bitumen MC 30
CharacteristicValueTest Method
Kinematic Viscosity at 60°C (cSt)30-60ASTM D-2170
Flash Point (top open cup)(°C)38 minASTM D-3143
Distillate, %volume of total distillate to at 360°C:25 maxASTM D-402
To 225°C40-70
To 260°C75-93
To 316°C
Residue from Distillation to 360°C (%Vol by difference)50 min
TEST ON RESIDUE FROM DISTILLATION
Viscosity at 60°C30-120ASTM D-2170
Penetration at 25°C (dmm)120-250ASTM D-5
Ductility at 25°C (cm)100 minASTM D-113
Solubility in Trichloroethylene (%wt)99 minASTM D-2042
Water Content (%vol)0.2 maxASTM D-95
Bitumen MC 70
CharacteristicValueTest Method
Kinematic Viscosity@ 60°C  (cSt)70-140ASTM D-2170
Flash Point (Top open cup)(°C)38 minASTM D-3143
Distillate, %volume of total distillate to @ 360°C:20 maxASTM D-402
to 225°C20-60
to 260°C65-90
to 316°C
Distillate, %volume of total distillate to @ 360°C:
to 225°Cto 260°Cto 316°C
55 minASTM D-402
TEST ON RESIDUE FROM DISTILLATION
Viscosity@ 60°C  (cSt)30-120ASTM D-2170
Penetration @ 25°C (dmm)120-250ASTM D-5
Ductility @ 25°C (cm)100 minASTM D-113
Solubility in Trichloroethylene (%wt)99 minASTM D-2042
Water Content (%vol)0.2 maxASTM D-95
Bitumen MC 300
CharacteristicValueTest Method
Kinematic Viscosity@ 60°C  (cSt)800-1600ASTM D-2170
Flash Point (Top open cup)(°C)66 minASTM D-3143
Distillate, %volume of total distillate to @ 360°C:-ASTM D-402
to 225°C20-60
to 260°C45-80
to 316°C
Residue from Distillation to 360°C  (%Vol by difference)75 minASTM D-402
Test on Residue from Distillation
Penetration @ 25°C (dmm)120-250ASTM D-5
Ductility @ 25°C  (cm)100 minASTM D-113
Solubility in Trichloroethylene (%wt)99 minASTM D-2042
Bitumen MC 3000
CharacteristicValueTest Method
Kinematic Viscosity@ 60°C  (cSt)3000-6000ASTM D-2170
Flash Point (Top open cup)(°C)66 minASTM D-3143
Distillate, %volume of total distillate to @ 360°C:-ASTM D-402
to 225°C0-15
to 260°C15-75
to 316°C
Residue from Distillation to 360°C  (%Vol by difference)80 minASTM D-402
Test on Residue from Distillation
Viscosity at 60°C30-120ASTM D-2170
Penetration at 25°C  (dmm)120-250ASTM D-5
Ductility at 25°C  (cm)100 minASTM D-113
Solubility in Trichloroethylene (%wt)99 minASTM D-2042
Water Content (%vol)0.2 maxASTM D-95

PACKING

  • Drum 220 Litr
  • Bulk
  • Flexi Tank